HomeMy WebLinkAbout2025-04-23 BOA Meeting Packet
Item No. 4.
Board of Adjustment Agenda
Staff Report
Meeting Date: 4/23/2025
Staff Contact:
AGENDA ITEM:
Director's Report.
SUMMARY:
BACKGROUND:
STAFF RECOMMENDATION:
ATTACHMENTS:
MINUTES
BOARD OF ADJUSTMENT
March 12, 2025
The Board of Adjustment of the City of Anna held a meeting at 6:00 p.m. on March 12, 2025, at the Municipal
Complex located at 120 W. 7th Street, to consider the following items.
1. Call to Order, Roll Call, and Establishment of Quorum.
The meeting was called to order at 6:10 p.m.
Board Members present were David Colgrove, Jon Hendricks, Elijah Nelms, Edward Culham, Jeffrey Petry,
Travis Bates, and Cory Halley. Staff present were Nader Jery, Everett Johnson, Sharon Lopez, Lauren Mecke,
Stephanie Scott-Sims, and Bret Wilkinson.
2. Invocation and Pledge of Allegiance.
Board Member Culham gave the invocation and led the Pledge of Allegiance.
3. Neighbor Comments: At this time, any person may address the Planning & Zoning Commission regarding
an item on this meeting Agenda that is not scheduled for Public Hearing. Also, at this time, any person may
address the Commission regarding an item that is not on this meeting’s Agenda. Each person will be
allowed up to three (3) minutes to speak. No discussion or action may be taken at this meeting on items
not listed on this Agenda, other than to make statements of specific factual information in response to a
neighbor’s inquiry or to recite existing policy in response to the inquiry.
There were no Neighbor comments.
4. Director's Report.
Ms. Scott-Sims reported that the City Council and Planning and Zoning Commission reviewed the
comprehensive plan update. The Planning and Zoning Commission will act upon it at the upcoming meeting on
March 18 and the City Council will do the same on March 25 meeting. The Planning and Zoning Commission
will also consider the adoption of an ordinance which clarifies the definition of a smoke shop and minimum
distances between them.
5. Approve Minutes of the January 8, 2025, Board of Adjustment Meeting
A motion was made by Board Member Bates to approve Item 6, seconded by Board Member Nelms. The vote
was unanimous in favor.
6. Conduct a public hearing/consider/discuss/action on a variance to the 60-foot vegetative buffer and two-
story building setback requirements. DHI Anna, Block A, Lot 1. Zoned Planned Development-Multi-Use
(PD-MU)/Restricted Commercial/General Commercial/Multiple-Family Residential - High Density/Single-
Family Residential SF-60/Single-Family Residential - Zero lot line/Single-Family Townhome (C-1/C-2/MF-
2/SF-60/SF-Z/SF-TH) (Ord. No. 881-2020). (V 25-0001)
Owner: DHIC - Lindsey Place LLC.
Mr. Johnson explained that the 7 D. R. Horton single-family plats that butted up against DHI’s 60-foot buffer of
their multifamily homes overlapped by 7’. DHI and D. R. Horton came to an agreement to ask for a variance of
the 60-foot buffer because changing the single-family plats would make them out of compliance for minimum
lot square footage.
Board Member Halley asked if property lines do not move, why had these properties encroached upon buffer.
Hayden Moses from DHI explained that the surveys for each property were done a year apart and no one
caught the discrepancy until after DHI had finished construction on the apartment buildings and D. R. Horton
had completed road construction and plats.
Board Member Hendricks asked why D. R. Horton was not asking for the variance because they were the ones
who created the issue. Mr. Moses explained that because DHI owned D. R. Horton, it was just as easy for
them to ask for the variance.
Chairman Culham opened a Public Hearing at 6:37 p.m. The Public Hearing was closed at 6:37 p.m.
A motion was made by Board Member Bates and seconded by Board Member Petry to approve the variance.
The vote was unanimous in favor. The motion passed.
7. Adjourn.
The meeting was adjourned at 6:38 p.m.
______________________________________
Chairman Edward Culham
ATTEST:
_________________________________
Stephanie Scott-Sims
Director of Development Services
Item No. 5.b.
Board of Adjustment Agenda
Staff Report
Meeting Date: 4/23/2025
Staff Contact: Lauren Mecke
AGENDA ITEM:
Conduct a Public Hearing/Consider/Discuss/Action on a variance request regarding
Urban Crossing, Block A, Lot 19R (3019 Crossing Way), zoned Single-Family - Large
Lot (SF-E), for a variance of 46 feet of encroachment to the structure setback from the
right-of-way within the required setback of 125% of the support structure height from
public rights-of-way.
SUMMARY:
The applicant is requesting a variance of the setback from the R.O.W. by a reduction of
46 feet from 150 feet to 104 feet.
BACKGROUND:
Within Section 9.04.037 (Infrastructure Use-Specific Standards) of Article 9.04 (Zoning
Ordinance), the regulations define the setback of a Radio, TV, or Microwave
Operations, Commercial (Communications Tower) as 125 percent (125%) of the height
of the support structure.
Sec. 9.04.037. Infrastructure Use-Specific Standards
(b) Radio, TV, or Microwave Operations, Commercial.
(4) General Requirements.
(G) Setback, Separation, and Screening of Ground Equipment Requirements.
(ii) Support structures, except for network node poles, must be set back a
minimum of 125 percent of the support structure height from public rights-of-
way.
As shown in the attached elevation, the support structure will be 120 feet in height with
a required setback of 150 feet.
The applicant's request and layout show the distance from the center of the support
structure to the Rosamond Parkway right-of-way as 104'-3". The applicant has also
provided a fall radius letter. This letter provides justification that the structure will meet
the intent of the setback in a failure of the structure were to occur and would not fall into
the right-of-way.
Surrounding land uses
Direction Land Use Zoning
North & Two Single-Family Detached SF-E
West Dwellings and one Vacant lot
East Vacant lot Planned Development (Liberty
Hills)
South Rosamond Parkway - 120' right-of-way
and vacant land within the 170'
Texas Power & Light Company
easement
Planned Development (Villages
of Hurricane Creek - North)
Within Section 9.04.053 (Relief Procedures) of Article 9.04 (Zoning Ordinance), the
Board of Adjustment shall hold a public hearing and use the following criteria to make
their determination:
Sec. 9.04.053 Relief Procedures
(a) Variances.
(6) Approval Criteria. The Board of Adjustment shall not approve a variance
unless it finds that:
(A) The variance is not contrary to the public interest, and
(B) Due to special conditions, a literal enforcement of the ordinance would
result in unnecessary hardship, and
(C) The spirit of the varied provision is observed and substantial justice is done.
STAFF RECOMMENDATION:
The Board shall consider the facts of the case to determine if the variance should be
granted.
ATTACHMENTS:
1. Locator - Urban Crossing, Block A, Lot 19R
2. Applicant's Variance Request - Urban Crossing, Block A, Lot 19R
3. Elevation - Urban Crossing, Block A, Lot 19R
4. Site Layout - Urban Crossing, Block A, Lot 19R
5. Fall Radius Letter - Urban Crossing, Block A, Lot 19R
HURRICANE
CREEK
CIR
WILLOWTERRACELN
N
CENTRAL
EXPY
COUNTY
ROAD
368
MEADOWSPRINGSLN
HURRICANE CREEK LN
CROSSING DR
URBAN WAY
HONEYCRESTCIR
SILVE
R
M
O
N
T
C
I
R
SANDPEBBLECIR
WROSAMONDPKWY
Pil
ot
Grove
C
r
eek
East
ForkTrinityRive
r
Sis
ter
G
r
oveCreek
Van Alstyne
75 SH 121
SH 5
Subject
Property
200' Notice
Boundary
City Limits
ETJ
¯
0 300 600150
Feet
April 2025
Urban Crossing, Block A, Lot 19R
Variance Request
Inset Map
1
VARIANCE REQUEST
Applica on: Variance from Public Right-of-Way Setback of 125% of Antenna Support Structure Height in
Zoning Ordinance Sec on 9.04.037(b)(4)(G)(ii)
Applicant: Hemphill, LLC
Hemphill Site Name: 1781 Fitzhugh
Project: 120’ monopole commercial antenna support structure with 10’ lightning rod
Project Area: A 2,445 sq (.0561 acre) leased por on of Lot 19, Block A of the Urban Crossing Plat
Property Address: 3019 Crossing Drive, Anna, TX 75409
Property ID: 2700407
Geographic ID: R-9650-00A-019R-1
Related Specific Use Permit Applica on: SUP 25-0003
Property Owner: Urban Crossing Homeowners Associa on
Introduc on
Hemphill, LLC is proposing a 120’ monopole commercial antenna support structure that will
accommodate Verizon Wireless and 3 addi onal providers on a por on of Lot 19, Block A of the Urban
Crossing Plat leased from the Urban Crossing Homeowners Associa on (“HOA”). The leased project area
is 2,445 sq (.0561 acre). This parcel is addressed as 3019 Crossing Drive, Anna, TX 75409. The
Property ID is 2700407 and the Geographic ID is R-9650-00A-019R-1. Lot 19, Block A is designated on
the plat as a Common Area dedicated to and maintained by the HOA. Sec on 5.17 of the Urban Crossing
“Declara on of Covenants, Condi ons and Restric ons” dated September 5, 2022 specifically allows for
HOA approval of a tower on the HOA lot. The HOA voted 25-2 to approve this project on the parcel at an
HOA mee ng on February 20, 2024.
The only current uses of the parcel are u lity and communica ons uses. There is a Texas Power & Light
Company (TXU Energy) u lity easement with a transmission tower and lines on the parcel. There is also
a high-speed internet provider serving the Urban Crossing neighborhood from an exis ng 60’ la ce
tower on the parcel. This site tower is to be removed and the antennas transferred to the proposed
Hemphill monopole.
This parcel is zoned SF-E Single-Family Residen al Estate – Large Lot under the previous zoning
ordinance. City of Anna Code of Ordinances Sec on 9.04.03(b)(4)€ indicates that “commercial antennas
and antenna support structures are prohibited in residen al districts on lots used or pla ed for single-
family, two-family, or single-family a ached dwelling purposes”. On November 13, 2024, the City of
Anna Board of Adjustment found that this prohibi on did not apply to the subject parcel because the lot
is not used or pla ed for residen al purposes and that the applicant is not prohibited from seeking a
Specific Use Permit (Board of Adjustment Order 2024-002).
In the course of reviewing our Specific Use Permit applica on for this project (SUP 25-0003), planning
staff pointed out that the distance from the public right-of-way for the future Rosamond
Parkway/County Road 370 extension to the south does not meet the required setback from a public
right-of-way required by City of Anna Zoning Ordinance Sec on 9.04.037(b)(4)(G)(ii). This Variance
applica on seeks relief from that requirement to allow the distance as drawn (104’-3” from tower center
to the public right-of-way) rather than the 150’ required by the ordinance.
2
Variance Requested
City of Anna Zoning Ordinance Sec on 9.04.037(b)(4)(G)(ii) contains the following setback requirement
from public rights-of-way:
(ii) Support structures, except for network node poles, must be set back a minimum of 125
percent of the support structure height from public rights-of-way.
As shown in the eleva on view on Sheet C3-1 of the drawings provided, this monopole commercial
antenna support structure will be 120’ high, so the required public right-of-way setback distance is 150’
(125% of 120’).
However, as shown on Sheet C1-4 of the drawings, the center of the monopole commercial antenna
support structure is 104’-3” from the public right-of-way for the future Rosamond Parkway/County Road
370 extension.
Consequently, applicant Hemphill, LLC seeks a variance from the 150’ public right-of-way setback
required by Sec on 9.04.037(b)(4)(G)(ii) to allow construc on as drawn.
Difficulty/Hardship
City of Anna Zoning Ordinance Sec on 9.04.074(e) authorizes the Board of Adjustment to grant
variances from the requirements of the ordinance.
In this case, the unique shape and size of the lot presents an unusual and prac cal difficulty/hardship
preven ng compliance with the 150’ public right-of-way setback required by Sec on
9.04.037(b)(4)(G)(ii).
The lease area for this project is ghtly wedged between the north property line and the current
construc on access drive for the subdivision and hemmed in by HOA subdivision easements and building
setback lines to the west and the Texas Power & Light Company (TXU Energy) u lity easement to the
east. Survey Sheet 1 on the second page of the drawings shows the size and shape of the parcel as well
as the exis ng easements and rights-of-way that constrain this site. Further measurements are included
on Sheet C1-4. Because of the parcel’s unique size and shape, there is not any loca on on the parcel
that can meet a 150’ setback from the public right-of-way for the future Rosamond Parkway/County
Road 370 extension.
Public Interest/Impact
This site is needed to address urgent community need for be er service from both coverage and
capacity standpoints. Documenta on from Verizon Wireless regarding the need for has been provided
as part of the SUP applica on. Also, residents of the Urban Crossing subdivision have previously tes fied
to the Board of Adjustment regarding the poor service in their homes and the difficul es in personal and
business communica on as well as their concern for their safety in emergency situa ons.
This site will not just address Verizon’s service to this community, it will also be essen al infrastructure
for future providers to serve this community as well. As shown on Sheet C3-1 of the drawings provided,
the proposed tower is designed to accommodate three addi onal future providers at centerlines of 103’,
91’, and 79’ as well as antennas from the nearby internet service provider tower to be removed.
3
Improved wireless service in this area is not just a ma er of convenience, it is cri cal to public health,
safety, and general welfare. The service provided by this facility will provide emergency informa on such
as amber alerts, weather alerts, radar informa on and other informa on and instruc ons during
emergencies. It will support 911 calls (most of which are made from wireless devices) in the event of
accident, health crisis, fire, natural disaster, or other emergency.
Gran ng the requested variance will not have a nega ve impact on the public right-of-way for the future
Rosamond Parkway/County Road 370 extension. To ensure this, the monopole commercial antenna
support structure will be designed to have a 0’ fall radius as shown by the fall radius le er provided from
Professional Engineer Jason Lambert.
Compara vely, the exis ng Texas Power & Light Company (TXU Energy) transmission tower on the parcel
is much closer to County Highway 368 and the power lines cross over the public right-of-way for the
future Rosamond Parkway/County Road 370 extension.
Conclusion
Based on the unique size and shape of the lot preven ng compliance, the public interest served by this
project, and the lack of nega ve impact on the public right-of-way for the future Rosamond
Parkway/County Road 370 extension, applicant respec ully requests approval of a Variance from the
150’ public right-of-way setback required by Sec on 9.04.037(b)(4)(G)(ii).
Respec ully submi ed,
_________________________________________________________ Date: 3/14/2025
Faulk & Foster, by Ralph Wyngarden, for Applicant Hemphill, LLC
SCALE
REVISION:SHEET NUMBER:
C3-1
1305 NORTH LOUISVILLE AVE
TULSA, OK 74115
(918) 834-2200
ISSUED FOR:
CHECKED BY:
DRAWN BY:
911 ADDRESS:
DESCRIPTIONREVDATE
PROJECT NAME:
PROJECT NO:
0 FOR APPROVAL03/13/25
1781
RS
RGH/MK/SLT
FITZHUGH
TBD CR 368, ANNA, TX 75409
SPECIALTY TELECOMUNICATIONS
SERVICES, LLC
13431 BROADWAY EXT., SUITE
120. OKLAHOMA CITY. OK 73114
405-753-7167
PROPERTY OWNER URBAN CROSSING HOA
OWNER ADDRESS PO BOX 384 ANNA, TX 75409-00384
OWNER CONTACT NAME STEVE S.
OWNER PHONE #214-244-1541
APPROVAL
TOWER ELEVATION
0
ETHAN T. VAN METER
PROFESSIONAL ENGINEER - TEXAS
REGISTRATION NO.: 149870
FIRM NO.: F-16740
N.T.S.
THESE DRAWINGS ARE NOT INTENDED TO REFLECT THE
STRUCTURAL INTEGRITY OF THE TOWER. THE PROPOSED
ANTENNAS AND TRANSMISSION LINES SHOWN ARE
REPRESENTATIVE IN NATURE AND DO NOT REFLECT THE
ACTUAL CONFIGURATIONS REQUIRED. THE CONTRACTOR
SHALL REFER TO THE STRUCTURAL ANALYSIS OF THIS
TOWER SITE FOR THE APPROVED LOCATION AND
CONFIGURATION OF ALL ANTENNAS AND TRANSMISSION
LINES. ALL ANTENNAS MUST BE MOUNTED AND THE
TRANSMISSION LINES CONFIGURED IN STRICT ACCORDANCE
WITH THE STRUCTURAL ANALYSIS.
COMPOUND FENCE
SEE SHEET C6-1
120' MONOPOLE TOWER
VERIZON ANTENNAS AT
115'-0" RAD CENTER ELEVATION
120'-0" TOP OF TOWER
10'-0" LIGHTNING ROD
130'-0" TOTAL HEIGHT WITH APPURTENANCES
MICROWAVE DISH(ES) AT
65'-0" RAD CENTER ELEVATION
FUTURE CARRIER ANTENNAS AT
91'-0" RAD CENTER ELEVATION
FUTURE CARRIER ANTENNAS AT
103'-0" RAD CENTER ELEVATION
FUTURE CARRIER ANTENNAS AT
79'-0" RAD CENTER ELEVATION
MICROWAVE DISHES RELOCATED FROM
EXISTING TOWER AT
TBD RAD CENTER ELEVATION
TOWER ELEVATION
SP 25-001
URBAN CROSSING
LOT 19R, BLOCK A.
0.898 ACRES
CITY OF ANNA,
COLLIN COUNTY,
TEXAS.
SURVEY BY POINT TO POINT LAND
SURVEYORS DATED 05/08/25
ABSTRACT NAME: URBAN CROSSING
0 20' 40'
SCALE: 1"=20'
SCALE
REVISION:SHEET NUMBER:
C1-4
1305 NORTH LOUISVILLE AVE
TULSA, OK 74115
(918) 834-2200
ISSUED FOR:
CHECKED BY:
DRAWN BY:
911 ADDRESS:
DESCRIPTIONREVDATE
PROJECT NAME:
PROJECT NO:
0 FOR APPROVAL03/13/25
1781
RS
RGH/MK/SLT
FITZHUGH
TBD CR 368, ANNA, TX 75409
SPECIALTY TELECOMUNICATIONS
SERVICES, LLC
13431 BROADWAY EXT., SUITE
120. OKLAHOMA CITY. OK 73114
405-753-7167
PROPERTY OWNER URBAN CROSSING HOA
OWNER ADDRESS PO BOX 384 ANNA, TX 75409-00384
OWNER CONTACT NAME STEVE S.
OWNER PHONE #214-244-1541
APPROVAL
OVERALL SITE PLAN
0
ETHAN T. VAN METER
PROFESSIONAL ENGINEER - TEXAS
REGISTRATION NO.: 149870
FIRM NO.: F-16740
1"=20'
EXISTING
TRANSMISSION
TOWER
104'-3"
60'
55'
66'-4"
26'-5"66'-6"
91'-5"
EXISTING 80' TOWER
TO BE REMOVED BY
OWNER. RELOCATE
EXISTING ANTENNAS
AND EQUIPMENT TO
NEW TOWER
20
'
U
T
I
L
I
T
Y
A
N
D
DR
A
I
N
A
G
E
E
A
S
E
M
E
N
T
25' PRIVATE
ACCESS
EASEMENT
35' UTILITY AND
DRAINAGE
EASEMENT
RIGHT-OF-WAY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PRO
P
E
R
T
Y
L
I
N
E
PRO
P
E
R
T
Y
L
I
N
E
25' BUILDING SETBACK LINE
75' BUILDING SETBACK
LINE
65' BUILDING SETBACK
LINE
EXISTING PRIVATE
GRAVEL DRIVEWAY
30' INGRESS-EGRESS &
UTILITY EASEMENT
PROPOSED 120'
MONOPOLE TOWERPROPOSED 6'-0"
STRONGHOLD IRON
FENCE
PROPOSED
LEASE AREA
OVERALL SITE PLAN
SP 25-001
URBAN CROSSING
LOT 19R, BLOCK A.
0.898 ACRES
CITY OF ANNA,
COLLIN COUNTY,
TEXAS.
SURVEY BY POINT TO POINT LAND
SURVEYORS DATED 05/08/25
ABSTRACT NAME: URBAN CROSSING
NOTES:
1. SEE SHEET L1-1 FOR LANDSCAPING PLAN
2. SEE SHEET 5-1 FOR PRE AND POST DEVELOPMENT
TOPOGRAPHY
147'-4"
32'-7"
10'-6"
175'-4"
±13'-9"
99'-5"
25'
20'
PROPOSED 3' LANDSCAPE BUFFER
(SEE SHEET L1-1 FOR DETAILS)
SITE DATA SUMMARY TABLE
LAND USE T.B.D.
AREA(SQ.FT)/ACREAGE 39117/0.898
LOT AND BLOCK DATA LOT 19R, BLOCK A
116'
56'-9"
127'-3"
279'-1"
117'-2"
247'-6"74'-3"
1 MI. RADIUS VICINITY MAP (NOT TO SCALE)
1201 S Sheridan St
South Bend, IN 46619
Phone: 574-288-3632
Fax: 574-288-5860
www.nelloinc.com
January 12, 2025
Hemphill
1350 North Louisville
Tulsa, OK, 74115
Re: Nello Tower Fall Radius – Nello 125’ NTP Pole Tower
Project Name: 1781 Fitzhugh / (33.363511, -96.588172)
Nello Job #: RFQ
To Whom It May Concern:
This letter is regarding your inquiry about the expected performance of your proposed tower designed by Nello
Corporation based on site-specific criteria.
Our towers are designed to meet or exceed industry standards defined by TIA-222-G, “Structural Standards for
Antenna Supporting Structures and Antennas” (TIA Standard). It is our opinion that the possibility of a tower
collapse is very unlikely. The tower is designed using extreme wind and ice conditions. In fact, wind speeds
specified by the TIA Standard are 50-year wind speeds. That is, they have only a 2% statistical chance of occurring
in any given year.
This tower will be designed using the following wind conditions as a minimum: a 106 mph 3-second gust wind
speed with no ice and a 30 mph 3-second gust wind with .75” ice. The TIA Standard specifies 106 mph as the wind
speed required for Collin County, TX. The “3-second gust wind speed” refers to a wind measured at 33 feet above
the ground. Equations in the TIA Standard take into account that wind speed escalates with increasing height of the
tower.
Although we cannot guarantee exactly how a tower would fall if it were to fail, the most likely mode of failure
would be a buckling failure of one of the tower sections due to excessive wind loading. Nello will design the tower
to stay within a fall radius of 0 feet based on design stress levels in accordance with the TIA-222-G Standard and the
currently adopted IBC.
The fall radius statement above assumes proper foundation construction and tower installation. The foundation
design should be reviewed to ensure that no foundation limit state governs the entire structural system and negates
the fall radius design. The fall radius expectancy requires that the foundation be designed with a capacity greater
than that of the tower capacity. If the foundation design used in association with this tower is performed by a third
party then Nello must be provided the opportunity to review the design in order to confirm that the fall radius
remains satisfactory. If for some reason Nello does not provide the tower design or is not given the opportunity to
design or review the foundation for this specific project then the content of this letter becomes void.
If you have any other questions or concerns regarding the design of your site-specific tower, please contact our
engineering or sales department.
Sincerely,
Jason M. Lambert, PE
Vice President of Engineering
EXHIBIT H