HomeMy WebLinkAboutPZ Res 2025-09-0179 Victoria Falls Center, Block A, Lot 2, Site Plan (SP 25-0016)Site Data Summary Table General Site Data Zoning PD-C Ord. 119-2003 Proposed Land Use Auto Repair, Light (SUP) Lot Area (per plat)38,352 Lot Area 0.88 Building Footprint Area (Approximate)4,650 Area Covered by Canopy 96 Maximum Building Height (# Stories)1 Maximum Building Height (Feet)35' Lot Coverage 12% Floor Area Ratio 1/8 Parking Parking Required 2 per 1000 SF 10 Standard Parking Provided 17 Accessible Parking Required 2 Accessible Parking Provided 2 Total Parking Provided 19 Landscaping Area Landscape area requirement (15% of street yard)1040.1 Landscape Area Requirement (15% of entire site)5752.8 Street Yard Area 6934 Street Yard Landscape Provided 6564 Internal LS Provided 5,177 Total LS Area Provided:11,741 Other Planting Area 1,215 Permeable Areas Permeable Pavement 0 Other Permeanble Area 0 Total permeable Area 12,956 Impervious Area Building Area 4,650 Sidewalks, Pavement, and other Impervious Flatwork 19,016 Other Impervious Area (curbs)1,730 Total Impervious Area 25,396 Total Landscape Area, Impervious Area, Permeable Area 38,352 STREET FRONT LANDSCAPE AREA: 5,382 SF EXISTING 24' FIRE LANE 9' - 0"9' - 0"9' - 0"10' - 0"9' - 0"9' - 0"9' - 0" 18 ' - 0 " OV E R H A N G 2' - 0 " 17' - 0"9' - 0"9' - 0" 78' - 9 5 / 8 " 88' - 2 1 / 2 " 55' - 1" 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 10' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0" 9' - 0" 27' - 3 7 / 8 " EX I S T I N G 2 4 ' F I R E LA N E E A S E M E N T EXISTING 7.5' WATER EASEMENT 10' EXISTING WATER EASEMENT 20' LANDSCAPE SETBACK 18' - 0" OVERHA N G 2' - 0" 20' LANDSCAPE SETBACK EXISTING TREE TO REMAIN 25' BUILDING SETBACK (BY PLAT) 20' WATER EASEMENT EXISTING WROUGHT IRON FENCE EXISTING MONUMENT SIGNAGE CANOPY TREES IN LANDSCAPE BUFFFER89° 31' 55" 142.75' N W 24 ° 2 1 ' 5 8 " 14 8 . 7 6 ' N W 89° 36' 26" 202.69' N E 0° 0 0 ' 4 0 " 72 . 3 8 ' N W (89o 36'24"E PLAT) 21 0 . 4 6 N 0 0 o 2 4 ' 3 6 " W SCREENING SHRUBS - SUNSHINE LIGUSTRUM @ 42" O.C., 5 GA SCREENING SHRUBS ALONG FM 455 FRONTAGE 5 GALLON NEEDLEPOINT HOLLIES @ 2'-5" O.C. SCREENING SHRUBS BETWEEN USES EXISTING CURB INLET DUMPSTER ENCLOSURE 7' SCREEN WALL TO MATCH BUILDING WITH 7' SOLID GATES (2) 8 YARD BINS EXISTING SANITARY SEWER EASEMENT PROPOSED SINGLE STORY BUILDING 30'-0" T.O. PARAPET LIGHT AUTO MAINTENANCE 4,880 GSF STREET YARD: 6,9341 SF VI C T O R I A F A L L S D R I V E 50 ' R . O . W . ( E X I S T I N G ) W. WHITE STREET (F.M. 455) VARIABLE R.O.W. (EXISTING) BLOCK A LOT 2 38,352 SF/.88 ACRES TEXAS BANK BLOCK A LOT 3 25,693 SF/ .59 ACRES VICTORIA FALLS CENTER ADDITION INSTRUMENT NO. 20191217001606230 ZONING: PD119-2003 USE: BANK RGR DEVELOPMENT COMPANY LP BLOCK A LOT 1 204,760 SF/4.70 ACRES VICTORIA FALLS CENTER ADDITION INSTRUMENT NO. 20210729001531890 ZONING: PD 119-2003 USE: RETAIL THE FALLS HOMEOWNERS ASSOCIATION BLOCK B LOT 10 6961 SF/.15 ACRES FALLS PHASE 1A ADDITION INSTRUMENT NO. 103194 VOLUME 5708 PAGE1069 ZONING: PD 119-2003 USE: OPEN SPACE 716 71 6 716 716 718 718 718 714 716 714 714 714 25' BUILDING SETBACK (BY PLAT) 10' REAR YARD SETBACK 5' SIDE YARD SETBACK PROPOSED DRIVE WAY PR O P O S E D DR I V E W A Y 25'x25' VISIBILITY EASEMENT PR O P O S E D PA R K I N G PROPOSED PARKING PROPOSED PARKING 18' - 8 3 / 4 " HVAC CONDENSERS R30' - 0 " R30' - 0" R30' - 0" R30 ' - 0 " PROPOSED BARRIER FREE RAMPS AND CROSSWALK JONES LEON & LINDA PHASE 3 BLOCK T LOT 8 OAK HOLLOW ESTATES INSTRUMENT NO. 59863 VOLUME 5913 PAGE 0519 ZONING: PD-R 2000-15 USE: SINGLE FAMILY THE FALLS HOMEOWNERS ASSOCIATION BLOCK D LOT 21 7,375 SF/.17 ACRES FALLS PHASE 1A ADDITION INSTRUMENT NO. 103194 VOLUME 5708 PAGE1069 ZONING: PD 119-2003 USE: OPEN SPACE ORL I LLC BLOCK D LOT 20R-2A 50,530 SF/1.16 ACRES FALLS PHASE 1A ADDITION INSTRUMENT NO. 20180118000071740 ZONING: PD 119-2003 USE: RETAIL ELHODOLI AHMAD Y PHASE 3 BLOCK T LOT 7 OAK HOLLOW ESTATES INSTRUMENT NO. 94121 VOLUME 5697 PAGE 2982 ZONING: PD-R 2000-15 USE: SINGLE FAMILY BARAKAT ISSAM PHASE 3 BLOCK T LOT 6 OAK HOLLOW ESTATES INSTRUMENT NO. 20140310000219540 ZONING: PD-R 2000-15 USE: SINGLE FAMILY ORTEGA ISAMAR & JOSE EDMUNDO PHASE 3 BLOCK T LOT 5 OAK HOLLOW ESTATES INSTRUMENT NO. 20210309000470090 ZONING: PD-R 2000-15 USE: SINGLE FAMILY QIAN WEI PHASE 3 BLOCK T LOT 4 OAK HOLLOW ESTATES INSTRUMENT NO. 20160412000435550 ZONING: PD-R 2000-15 USE: SINGLE FAMILY JOHNSON JOHN PHASE 3 BLOCK T LOT 9 OAK HOLLOW ESTATES INSTRUMENT NO. 20111003001051300 ZONING: PD-R 2000-15 USE: SINGLE FAMILY QUIROZ RAUL C PHASE 3 BLOCK T LOT 10 OAK HOLLOW ESTATES INSTRUMENT NO. 20120829001076170 ZONING: PD-R 2000-15 USE: SINGLE FAMILY EXISTING CURB INLETEXISTING SS MANHOLE EXISTING FIRE HYRDRANT REPAIR EXISTING CONCRETE IN THIS AREA TO MAINTAIN 24' FIRE LAND AND 30' RADIUS R5' - 0 " RELOCATED FIRE HYDRANT TO FACE FIRE LANE 18 ' - 0 " 2' - 0 " FRO M F A C A D E 5' - 1 0 " THOR OVERLAY DISTRICT 50' BUILDING SETBACK 15' - 1 " NEW LIGHT POLE NEW LIGHT POLE NR NR NR SL ? SL SL NP KF PARKING SCREENING 5 GAL KARL FORESTER GRASS @ 42" O.C. REAR SCREENING 5 GAL NEEDLEPOINT HOLLIES @ 36" O.C. 7 GAL N.R. STEVENS HOLLIES @36" O.C. US 7 5 C E N T R A L E X P R E S S W A Y FM 455 / WHITE STREET VI C T O R I A F A L L S SITE VICINITY MAP - NOT TO SCALE TRUE NORTH G R E E N L I G H T STUDIO, LLC © Greenlight Studio, LLC www.greenlight.company Applicant: Greenlight Studio LLC 100 N. Cottonwood Drive Suite 104 Richardson, Texas 75080 v: 214.810.4535 Owner: Texas Bank P.O. Box 1990 Henderson, Texas 75653-1990 v: 903.657.1466 .88 ACRES City of Anna, Collin County, Texas F. T. Duffau Survey, Abstract No. 288 Prepared September 17, 2025 VICTORIA FALLS CENTER ADDITION BLOCK A, LOT 2 City Project No. SP 25-0016 Site Plan 1" = 20'-0"1 Site Plan 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Buildings 6,000 square feet or greater shall be 100% fire sprinkled. Fire lanes shall be designed and constructed per city standards. Handicapped parking areas shall be designed and provided per city standards and shall comply with requirements of the current, adopted International Building Code. FIVE-foot wide sidewalks shall be provided per the City design Manual in the public Right of Way, unless a sidewalk easement is provided for a meandering sidewalk or an alternative design is approved by the city. Barrier-free ramps, per city standards, shall be provided on sidewalks at all curb crossings. Mechanical units, dumpsters, and trash compactors shall be screened in accordance with the Zoning Ordinance. All signage contingent upon approval by Building Inspections Department. Approval of the site plan is not final until all engineering plans are approved. Open storage, where permitted, shall be screened in accordance with the Zoning Ordinance. Outdoor lighting shall comply with illumination standards within city ordinance. Please contact the Building Inspections Department to determine the type of construction and occupancy group. All private electrical transmission, distribution, and service lines must be underground. Uses shall conform in operation, location, and construction to the following performance standards in the Zoning Ordinance: noise, smoke and particulate matter, odorous matter, fire or explosive hazard material, toxic and noxious matter, vibration, and/or other performance standards. All proposed paving shall be concrete per city of Anna Standards. 0'10'20'40'80' PRELIMINARY SITE PLAN NOTES SCALE = 1:20 N APPROVED September 19, 2025 PLANNING DEPARTMENT CITY OF ANNA