Loading...
HomeMy WebLinkAboutPZ Res 2025-02-0106 The Parks at Foster Crossing, Phase 1, Block F, Lot 17X, Site Plan697 69 6 S89°29'43"E 120.00' S 4 5 ° 2 0 ' 5 1 " E 7 2 . 7 7 ' GARDENDA L E H O L L O W L A N E OL Y M P I C D R I V E F 15 THE PARKS AT FOSTER CROSSING PHASE 1 14 THE PARKS AT FOSTER CROSSING PHASE 1 13 THE PARKS AT FOSTER CROSSING PHASE 1 12 F 16X THE PARKS AT FOSTER CROSSING PHASE 1 I 55 THE PARKS AT FOSTER CROSSING PHASE 1I 1 THE PARKS AT FOSTER CROSSING PHASE 1 P 1 E 10 THE PARKS AT FOSTER CROSSING PHASE 1 E F 1 THE PARKS AT FOSTER CROSSING PHASE 1 F 17X 695 694 695 69 5 698 697 69 7 699 700 696 695 F F F 2 THE PARKS AT FOSTER CROSSING PHASE 1 F 3 THE PARKS AT FOSTER CROSSING PHASE 1 F 4 THE PARKS AT FOSTER CROSSING PHASE 1 F 5 THE PARKS AT FOSTER CROSSING PHASE 1 EV E R G L A D E S R O A D 39X THE PARKS AT FOSTER CROSSING PHASE 1 694 694 695 69 869 9 70 0 693 692 691 690 689 689690 691 692 693 0.593 AC 25,831.08 SQ. FT. 696 697 69 7 69 7 69 8 S 0 7 ° 4 6 ' 4 1 " W 1 2 0 . 0 0 ' N 0 0 ° 3 0 ' 1 7 " E 1 6 0 . 3 2 ' C2 66.65' S89°29'43"E 50.00' S82°13'19"E 4 0 . 8 8 ' 697 69 669 7 BEING 0.593 ACRES SITUATED IN THE DAVID E.W. BABB SURVEY, ABSTRACT NO. 33 G. STARK SURVEY ABSTRACT NO. 798 IN THE CITY OF ANNA, COLLIN COUNTY, TEXAS SITE PLAN THE PARKS AT FOSTER CROSSING PHASE I BLOCK F, LOT 17X ~AMENITY CENTER~ .HI O OD J STE C C CT TE SA ET STA I REG 3 O F 28 ETX N R LDRE CAANDS L EPAHSON Y 3 January 07, 2025 Preparation: December 23, 2024 JOHNSON VOLK CONSULTING 704 CENTRAL PARKWAY, SUITE 1200 PLANO, TEXAS 75074 PH. (972) 201-3100 CONTACT: CODY JOHNSON, RLA, ASLA, LI LANDSCAPE ARCHITECT: MERITAGE HOMES OF TEXAS, LLC 8840 CYPRESS WATERS BOULEVARD SUITE 100 COPPELL, TEXAS 75019 PH. (919) 219-8635 CONTACT: STEVEN COOK OWNER / DEVELOPER:LOCATION MAP (NOT TO SCALE) UTILITY NOTES 1.SANITARY SEWER LATERALS ARE SHOWN ON PLAN TO BE LOCATED WITHIN 5'-0' FROM THE BUILDING PAD. MEP PLANS WILL BE PROVIDED IN A SEPARATE SUBMITTAL THAT SHOWS THE CONNECTION OF THE PROPOSED PLUMBING FIXTURES TO THIS LATERAL LINE. A TWO-WAY CLEAN OUT WILL BE PROVIDED AT THIS CONNECTION AS WELL AT THE PROPERTY LINE. 2.WATER LATERAL LINES ARE SHOWN ON PLAN TO BE LOCATED 5'-0" FROM THE BUILDING PAD. MEP PLANS WILL BE PROVIDED IN A SEPARATE SUBMITTAL THAT SHOWS THE CONNECTION OF THE PROPOSED PLUMBING FIXTURES TO THIS LATERAL LINE. A CUT-OFF DRAIN VALVE WILL BE PROVIDED INSIDE A WATER CUT-OFF BOX WITH A LOCKABLE COVER AT THIS CONNECTION. 3.ANY EXISTING SERVICE TAP TO BE ABANDONED SHALL BE ABANDONED BY PLUG LOCATED 2'-0" FROM BACK OF CURB. SP1 20 10 SCALE 1" = 20' 0 20 N LOT 17X, BLOCK F SITE INFORMATION HANDICAP PARKING IS PROVIDED IN ACCORDANCE WITH ADA STANDARDS TOTAL IMPERVIOUS SURFACE:13,023.45 SF, 50.41% INTERIOR LANDSCAPE REQUIRED: (25,831.08 X 10%) 2,5831.10 SF INTERIOR LANDSCAPE PROVIDED: 13,023.45 SF SITE DATA SUMMARY TABLE GENERAL SITE DATA (LOT 17X, BLOCK F) ZONING (FROM ZONING MAP)SINGLE FAMILY RESIDENTIAL LAND USE (FROM ZONING & ORDINANCE)COMMUNITY CENTER, PRIVATE LOT AREA (SQUARE FEET & ACRES)25,831.08 SF/0.593 AC BUILDING FOOTPRINT AREA (SQUARE FEET)569.00 SF TOTAL BUILDING AREA (SQUARE FEET)569.00 SF BUILDING HEIGHT (# STORIES)1 STORY BUILDING HEIGHT (FEET - DISTANCE TO TALLEST BUILDING ELEMENT)22'-7" HT. LOT COVERAGE (PERCENT - X.XX%)4% PARKING PARKING RATIO (FROM ZONING ORDINANCE)MINIMUM 8 SPACES PER SUBDIVISION REGULATIONS REQUIRED PARKING (# SPACES)8 REQUIRED PROVIDED PARKING SPACES (# SPACES)10 ACCESSIBLE PARKING PROVIDED (# SPACES)1 PROVIDED LANDSCAPE AREA (INCLUDING TURF AREAS) REQUIRED INTERNAL LANDSCAPE AREA (SQUARE FEET - 8 SQUARE FEET PER PARKING SPACE) 136 S.F. REQUIRED ADDITIONAL INTERIOR LANDSCAPE AREA PROVIDED (SQUARE FEET)13,023.45 TOTAL LANDSCAPE AREA (SQUARE FEET)13,023.45 SITE PLAN NOTES: ·NO 100 YEAR FLOOD PLAIN EXISTS ON PROPERTY. ·NO PROTECTED TREES EXIST ON DEVELOPMENT SITE. ·LIGHTING FOR THE SUBJECT PROPERTY SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE CITY OF ANNA CODE OF ORDINANCES. ·FOR ALL BARRIER FREE RAMPS NOTED ON PLAN, REFERENCE THE CITY OF ANNA STANDARD CONSTRUCTION DETAILS. ·ALL SIDEWALKS IN FRONT OF HEAD-IN PARKING SHALL BE 6'-0" WIDTH. RESTROOM FACILITY FFE 697.75 TANNING LEDGE SWIMMING POOL 2,644 SF SHADE STRUCTURE POOL DECK INLET MH 25' BL EQUIP. ENCL. 5' BL AND FENCE MAINTENANCE EASEMENT G G WG WG SHADE STRUCTURE POOL DECK POOL DECK POOL DECK PROPOSED PLAYGROUND FACILITY BFR BFR 30 ' - 0 " 50 ' - 0 " R . O . W . LP LP BFR BFR 4 6 2 1 31'-0" 50'-0" R.O.W. IN L E T IN L E T BFR BFR BFR BFRBFR BFR INLET MH MH STORM RETAINING WALL BY OTHERS. REFER TO CIVIL PLANS FOR DETAILS, TYP. BFR BFR BFR BFR 6'-0" WIDTH CONCRETE SIDEWALK PER CITY STANDARDS. REFER TO CIVIL PLANS FOR DETAILS, TYP. 6'-0" WIDTH CONCRETE SIDEWALK PER CITY STANDARDS. REFER TO CIVIL PLANS FOR DETAILS, TYP. H/C 8'-0" WIDTH CONCRETE SIDEWALK PER CITY STANDARDS. REFER TO CIVIL PLANS FOR DETAILS, TYP. 8'-0" WIDTH CONCRETE SIDEWALK PER CITY STANDARDS. REFER TO CIVIL PLANS FOR DETAILS, TYP. 5'-0" WIDTH CONCRETE SIDEWALK PER CITY STANDARDS. REFER TO CIVIL PLANS FOR DETAILS, TYP. TR B B 9'-0" WIDTH CONCRETE SIDEWALK PER CITY STANDARDS. REFER TO CIVIL PLANS FOR DETAILS, TYP. END 5'-0" WIDTH CONCRETE SIDEWALK AT LOT LINE. REFER TO CIVIL PLANS FOR DETAILS, TYP. END 6'-0" WIDTH CONCRETE SIDEWALK AT LOT LINE. REFER TO CIVIL PLANS FOR DETAILS, TYP. 10'-0" U.E. & LS BUFFER 25' V . A . M . 25 ' B L 10 ' U . E . & L S B U F F E R PE D E S T R I A N E A S E M E N T PEDESTRIAN EASEMENT ST O R M WA T E R SA N . S E W E R 10 ' U . E . 15 ' B L STORM 10' U.E. 15' BL WATER SAN. SEWER 50'-0" DRAINAGE EASEMENT LEGEND BARRIER FREE RAMP EXISTING PARKING COUNT PROPOSED 1" DOMESTIC WATER METER HANDICAP PARKING SPACE BFR EXISTING WATER MAIN W/ VALVE EXISTING SANITARY SEWER MANHOLE EXISTING SANITARY SEWER EXISTING STORM RIGHT-OF-WAY 4 H/C EXISTING CURB INLET ORNAMENTAL METAL FENCE (6'-0" HT. AROUND SWIMMING POOL AREA) (2) - 4'-0" WIDTH SELF LATCHING, SELF CLOSING METAL GATEG 6'-0" HT. WOOD FENCE TO ACT AS POOL EQUIPMENT AND TRASH TOTE ENCLOSURE (2) - 4'-0" WIDTH SELF LATCHING, SELF CLOSING WOOD GATEWG PROPOSED 1.5" IRRIGATION WATER METER HANDICAP SIGN EXISTING CONTOUR INTERVAL PROPOSED CONTOUR INTERVAL FINISHED FLOOR ELEVATION 697 697 FFE 697.75 2 1 MH EXISTING LIGHT POLELP PROPOSED 1'-6" HT. STONE SEAT WALL EXISTING RETAINING WALL BENCH TRASH RECEPTACLETR B PROPOSED 4'-0" HT. SPLIT RAIL FENCE. STORM 10' U.E. 15' BL WATER SAN. SEWER INLET 10' U.E. 25' BL 25 ' B L 10 ' U . E . ST O R M SA N . S E W E R 10 ' U . E . 15 ' B L WA T E R 10 ' U . E . ST O R M SA N . S E W E R 10 ' U . E . 15 ' B L WA T E R WATER PE D E S T R I A N E A S E M E N T 6'-0" WIDTH CONCRETE SIDEWALK PER PREVIOUS PHASE, TYP. BFR 6'-0" WIDTH CONCRETE SIDEWALK PER PREVIOUS PHASE, TYP. 6'-0" HT. BOARD ON BOARD WOOD FENCE. RETAINING WALL BY OTHERS. REFER TO CIVIL PLANS FOR DETAILS, TYP. 31'-0" 50'-0" R.O.W. IRR.DOM. METER SIZESIZE WATER SERVICE WATER METER METER ID NUMBER SERVICE SAN. SIZE WATER METER SCHEDULE 6"X1"1 2 1" X1.5"1.5" 12'-6" 69 ' - 8 " 138'-6" PROPOSED PARALLEL PARKING 26 ' - 1 1 " EXISTING PARALLEL PARKING. 22 ' - 0 " 9'-0" 15'-2" 20 ' - 0 " PROPOSED 1'-6" HT. STONE SEAT WALL. 5' BL AND FENCE MAINTENANCE EASEMENT 9' - 0 " 22'-0" 5'-0" 4'-0" HT. SPLIT RAIL FENCE. CI T Y P R O J E C T N O . S P 2 4 - 0 0 0 8 EXHIBIT A APPROVED February 3, 2025 P&Z COMMISSION CITY OF ANNA