HomeMy WebLinkAboutOrd 377-2008 Adopting 2005 NEC NCTCOG amendments.pdfCITY OF ANNA, TEXAS ORDINANCE NO. 377-2008 AN ORDINANCE OF THE CITY OF ANNA, TEXAS, AMENDING ORDINANCE NO. 2005-193 BY ADOPTING THE 2005 EDITION OF THE NATIONAL ELECTRICAL CODE; ADOPTING THE NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS RECOMMENDED AMENDMENTS TO THE 2005 NATIONAL ELECTRIC CODE; PROVIDING A REPEALER CLAUSE; PROVIDING A SAVINGS CLAUSE; AND PROVIDING FOR AN EFFECTIVE DATE WHEREAS, the City Council has determined the need for revising the City's existing electrical code; and WHEREAS, the City Council has received recommendations for said revisions from qualified professionals in the building inspection trade; and WHEREAS, the City Council desires to adopt and implement said recommendations; now therefore BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF ANNA, TEXAS: Section 1. National Electrical Code Adopted. The city council hereby adopts the 2005 Edition of the National Electrical Code, replacing the 2002 Edition of the National Electrical Code, adopted by Ordinance No. 2005-193. Section 2 Amendments The City Council hereby adopts the North Central Texas Council of Governments Recommended Amendments to the 2005 National Electrical Code, attached hereto as Exhibit A and made an integral part of this ordinance. Section 3 Repeal Clause All parts of any ordinance in conflict with the provisions of this ordinance are to the extent of such conflict hereby repealed. Section 4 Savings Clause If any provision of this ordinance shall be held to be invalid or unconstitutional, the remainder of such ordinance shall continue in full force and effect the same as if such invalid or unconstitutional provision had never been a part hereof. Section 5 Effective Date This ordinance shall be effective upon the posting and/or publication of its caption as required by law and the City Secretary is hereby directed to implement such posting and/or publication. AYE 6 NAY 0 ABSTAIN 0 ATTESTED: APPROVED: CSecretary, Natha Wilkison ayor, Ken e h Pelham Ap1'�U0111111gbW//// /. OF a. Ord. No. 377-2008 Adopting 2005 NECAm Recommended Amendments to the 2005 National Electrical Code North Central Texas Council of Governments Region REGIONAL AMENDMENTS* —Section 230.71(A) add an exception. 230.71 Maximum Number of Disconnects (A) General. The service disconnecting means for each service permitted by 230.2, or for each set of service -entrance conductors permitted by 230.40, Exception Nos. 1, 3, 4, or 5, shall consist of not more than six switches or sets of circuit breakers, mounted in a single enclosure, in a group of separate enclosures, or in or on a svntchboard. There shall be no more than six sets of disconnects per service grouped in any one location. For the purpose ... {text unchanged)... shall not be considered a service disconnecting means. Exception: Multi oocupant Buildings. Individual service discnnnedtno means is limited to six for each occupant The number of individual disconnects at one location may exceed six REASON FOR CHANGE: This is currently the accepted installation practice of the region. No noteworthy complaints have surfaced. It is more reasonable than the current NEC requirements. It allows more than six disconnects grouped at one location. This also allows designers more flexibility in the placement of electrical meters and main service disconnects. "Section 300.11 add an exception. 300.11 Securing and Supporting. (A) Secured In Place. Raceways, cable assemblies, boxes, cabinets, and fittings shall be securely fastened in place. Support wires that do not provide secure support shall not be permitted as the sole support. Support wires and associated fittings that provide secure support and that are installed in addition to the ceiling grid support wires shall be permitted as the sole support. Where independent support wires are used, they shall be secured at both ends. Cables and raceways shall not be supported by ceiling grids. Exception Ceiling and support wires may be used for structural supports when the associated wiring is located in that area, not more than two raceways or cables supported per wire with a maximum nominal metric designation 16 (trade size i4"). REASON FOR CHANGE: To provide limited support of raceways and cables by ceiling grid support wire. *NOTE: Underlining indicates new words and phrases to be added to the 2005 National Electrical Code. Strikes, indicate existing words and phrases to be deleted. North Central Texas 1 of 2 0622/05 2005 NEC Amendments '*Section 310.15(B)(6) change to read as follows. 310.16 Ampacities for Conductors Rated 0-2000 Volts. (B) Tables. (6) 120!240 -Volt, 3 -Wire, Single -Phase Dwelling Services and Feeders. For dwelling units, conductors, as listed in Table 310.15(8)(6), shall be ... (text unchanged)... provided the requirements of 215.2, 220.61, and 230.42 are met. This Section shall not be used in conjunction with 220.82. REASON FOR CHANGE: To provide a more reasonable margin of safety for dwelling service and feeder conductor allowable ampacities. "Section 500.8(A)(1) change to read as follows. 500.8 Equipment. (A) Approval for Class and Properties. (1) Equipment shall be identified ... (text unchanged)... the maximum surface temperatures specified in 503.1. FPN: Luminaries (lighting fixtures) and other heat -producing apparatus ... (text unchanged}... see Exception No. 3 to 600.8(6). monufaet-Regs A -if WmklafiGn OF an owners engineering judgment. REASON FOR CHANGE: "Identified" is already defined in Chapter 1. END 'NOTE: Underlining indicates new words and phrases to be added to the 2005 National Electrical Code. Strikeeuts indicate existing words and phrases to be deleted. North Central Texas 2 of 2 06422105 2005 NEC Amendments