Loading...
HomeMy WebLinkAboutRes 2019-08-609 Hurricane Creek Reg Sewer Project Task OrderCITY OF ANNA, TEXAS RESOLUTION NO. 401q -02 -Lo A RESOLUTION OF THE CITY OF ANNA, TEXAS APPROVING AND AUTHORIZING THE CITY MANAGER TO FUND PRELIMINARY AND FINAL ENGINEERING SERVICES, AS IDENTIFIED IN THE EXECUTED TASK ORDER BY AND BETWEEN THE CITY OF ANNA, TEXAS AND BIRKHOFF, HENDRICKS & CARTER, LLP, FOR THE HURRICANE CREEK REGIONAL SEWER PROJECT IN AN AMOUNT NOT TO EXCEED FIVE HUNDRED SIXTY SEVEN THOUSAND SEVEN HUNDRED SIXTY DOLLARS AND ZERO CENTS ($567,760.00), AS SHOWN IN EXHIBIT "A" ATTACHED HERETO, AND PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, the Hurricane Creek Sanitary Sewer expansion project is shown in the City of Anna's Wastewater Collection System Master Plan as multiple Capital Improvement Program projects required for the growth of the community; and, WHEREAS, the City Council approved Resolution 2018-06-456 approving and authorizing the City Manager to act on the City's behalf in executing an engineering service task order with Birkhoff, Hendricks & Carter, LLP, for the Hurricane Creek Regional Sewer Project; and, WHEREAS, the City of Anna, Texas (The City) executed the engineering service task order on July 2, 2018 with Birkhoff, Hendricks & Carter LLP for the Hurricane Creek Regional Sewer Project (the Project); and, WHEREAS, the City previously funded Preliminary Engineering Services identified in the task order and more thoroughly described on page 9 and 10 in Exhibit "A" attached hereto; and, WHEREAS, this resolution will approve and authorize funding for Preliminary and Final Engineering Services for Task A, Task B, and Task C, being more thoroughly described on page 9 and 10 in Exhibit "A" attached hereto; and, WHEREAS, Sanitary Sewer Impact Fees shall be used to fund the total not to exceed amount of $567,760.00. NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ANNA, TEXAS THAT: Section 1. Recitals Incorporated The recitals above are incorporated herein as if set forth in full for all purposes. Section 2. Authorization of Funding. That the City Manager is hereby authorized to fund the services for Task A, Task B, and Task C as more thoroughly described on page 9 and 10 in Exhibit "A" attached hereto. PASSED AND APPROVED by the City Council of the City of Anna, Texas on this 27th day of August 2019. ATTEST: APPROVED: .9 City Secretary, Carrie L. Smith--, °• • Ia'yor, Nate Pike 111111111 N III 10\0 BIRKHOFF, HENDRICKS & CARTER, L.L.P. PROFESSIONAL ENGINEERS 11910 Greenville Ave., Suite 600 Dallas, Texas 75243 Phone (214) 361-7900 www.bbellp.com JOHN W. BIRKHOPF, P.R. GARY C. HENDRICKS, P.E. JOE R. CARTER, P.E, MATT HICKEY, Y.E. ANDREW MA'rA, JR., P.E, JOSEPH T. GRAJEWSKI, lll, P.E. June 6 DEREK B, CHANEY, P.E , 2018 CRAIG M. KERKHOFF, P,E, Mr. Joseph Johnson Director of Public Works City of Anna 111 North Powell Parkway Anna, Texas 75409 Re: General Engineering Services —Task Order Hurricane Creep Regional Sanitary Sewer Dear Mr. Johnson: In accordance with your request and our existing general engineering services agreement, we are pleased to submit this General Services Task Order letter for services related to the preparation of specifications, bidding documents and contract administration for: The Hurricane Creek Regional Sanitary Sewer GENERAL PROJECT DESCRIPTION Tlus project consists of approximately 48,700 linear feet of sanitAry sewer pipe ranging in size from 36 -inch to 12 -inch. Generally, the project is within the East Fork Trinity and Hurricane Creek drainage basins, with a small segment extending the existing Throckmorton Creek sanitary sewer line to the north. For the purpose of design and construction phasing, as well as 3rd party participation, the project is separated into six (6) segments, as indicated in Table 1 and shown in the enclosed "Exhibit All. General descriptions of the six project elements are as follows; T BPE Finn 526 ACEC Wellness Firm ---* Better Decisions - Meller Designs TBPLS Firnl 100318-00 IM015 conidmannium Iturricano creek rogionaI sewtMurrIca no creek regional sanitarysewer task urdccdocx Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 2 of 13 Project A: 36 -inch sanitary sewer line along the east side of the East Fork Trinity River. Limits are from the existing regional Yhrockmorton Sanitary Sewer line to the convergence of the East Fork and Hurricane Creek. Project B: 30 -inch and 33 -inch sanitary sewer along the east side of Hurricane Creek. Limits are from the convergence of the East Fork and Hurricane creek to the south side of FM 455. These sanitary sewer sizes are it? compliance with the build -out sizes shown on the City's sanitary sewer Masterplan. Project C: 18 -inch sanitary sewer along the east side of the East Fork Limits are from the convergence of the East Fork and Hurricane Creek up approximately 3,750 LF up the East Fork basin. Project D: 27 -inch and 30 -inch sanitary sewer along the east side of Hurricane Creek. Limits are from the south side of FM 455 to the south end of the Mantua development. With topographic limitations, three (3) sanitary sewer connection points far the Mantua development will be required. This project will extend to the western most portion of the development. These sanitary sewer sizes are in compliance with the build -out sizes shown on the City's sanitary sewer Masterplan. Project E. 12 -inch sanitary sewer that will connect to Project D above. This project will provide a sanitary sewer connection point to the middle portion of the Mantua development (west side of US 75). Project F: 15 -inch sanitary sewer line that will extend the existing Throckrnorton sanitary sewer line. This line will serve the eastern connection point of the Mantua development adjacent to the east side of US 75. This line size is in compliance with the build -out size shown in the City's sanitary sewer Masterplan, i j TBPE Firm 526 ACEC AHIP Firm =;N Better Decisions - Better Designs TBPLS Firm 100318-00 1:\7015 codid eAnna@018 hurricane creek regional aewetAhunlane creek regional sanitarysewer task order.doex Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 3 of 13 Based on our understanding of the project requirements, our opinion of probable project budget is summarized below: Table 1- Opinion of Probable Project Budget A copy of our itemized opinion of project budget for each project segment is attached as Appendix A for reference only. WE Firm 526 ACEC AN1P Firrn =;5 Better Decisions -!letter Designs WLS Finn 100318-00 1:\7015 eon1dMannA2018 hurricane creek regional sewer\hurricana creek regional sanitary sewer task order docx Project A Project B Project C Project D Project E Project F Total Opinion of Probable Construction Cost' $6,104 874 $2,345044 $893 074 $3 078 652 $811 519 $1037264 ' ' $14270,427 ' Bonds, Insurance & Mobilization $122,098 $46,901 $17,861 $61,573 $16,230 $20,745 $285,409 31d Party Inspection Services $91,573 $35,176 $13,396 $46,180 $12,173 $15,559 $214,056 Quality Control & Material Testis $152,622 $58,626 $22,327 $76,966 $20,288 $25,932 $356,761 Land Rights Acquisitions $750,000 $327,135 $200,000 $323,002 $172,176 $196,281 $1,968,595 Preliminary Engineering Part I. (A - B) 60% Design $250,379 $107,723 $47,105 $135,040 $45,389 $54,141 ' $634,602 ' Part V (A - D) Additional Services (Survey, Plat & FIN, Clearing, Meetings, $112,375 $69,000 $17,625 $70,250 $30,000 $28,375 $327,625 Expenses) Final En ineerm Part Il -IV Final Design to 100%, $293,797 $121,883 $53,295 $148,947 $49,365 $60,062 $733,677 Bidding & Const. Admin. Part V (E - F) Additional Services $11,350 $6,700 $6,800 $11,100 $4,800 $5,950 $46,750 Geotech, Expenses) Total Project Budget $7,834,068 $3,084,938 $1,266,983 $3,767,108 $1,151,940 $1,437,309 $18,542,396 A copy of our itemized opinion of project budget for each project segment is attached as Appendix A for reference only. WE Firm 526 ACEC AN1P Firrn =;5 Better Decisions -!letter Designs WLS Finn 100318-00 1:\7015 eon1dMannA2018 hurricane creek regional sewer\hurricana creek regional sanitary sewer task order docx Mr. Joseph Johnson Genera( Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 4 of 13 SCOPE of SERVICES It is anticipated that each of the six (6) segments will be designed, bid and constructed as separate and stand-alone projects. The scope of services below applies to all six (6) segments individually. Part I: Preliminary Engineering Phase A. Preliminary Engineering Report pertaining to the design flows and considered route of the project B. Set the alignment and preliminary grade of the project in order prepare and provide permanent sanitary sewer and temporary construction easement plat and field notes to r the City for land right acquisition purposes. Two (2) Design review meetings are included with the Preliminary Engineering Phase. Part 11: Final Design Phase Preparation of construction plans and specifications for the following: A. Construction Plan -Profile Sheets prepared at a scale of not less than 1"= 20'. B. Standard Details. C. Special Details. D. Cover Sheet, Location Map and Sheet Index. E. Submittals to State Regulatory Agencies, as required. F. Preparation of required Texas Department of Transportation permits, as required. G. Coordination with other Franchise Utility companies. H. Three (3) Design review meetings. I. Opinion of Probable Consti action Estimate. J. Preparation of Specifications and Contract Documents. K. Assist in procuring geotechnical engineering information or reports as the project requirements dictate. L. Printing of preliminary plans and specifications for review by the City. TBPE Firm 526 ACEC AMP Firnt _-* Better Decisions - Better Designs TBPLS Fain 1 003 18-00 ht701 S contdevlanna12018 hurticanc creek regional saverlhurricane creek regional sanitary sewer task order docx Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 5 of 13 Part III: Bidding Phase A. Assist the City staff in advertising for bids. This will include e -mailing "Notice to Contractors" to contractors experienced in this type of construction. City will have Notice published in local newspaper. B. Posting the plans for bid advertisement on Civeast. C. Provide bidding documents to City of Anna, Dodge Reports, and two other parties requested by the City. D. Assist during opening of bids and provide bidding tally sheets. E. Provide bid tabulation to City and contractors who submitted bids. F. Obtain the following information from the lowest bidder: 1. Past work history. 2. Physical resources to produce the project. Formulate opinion from information received and provide the City a summary of the opinion for their use in selection and award of the construction contract. G. After award of contract, furnish ten sets of prints of the final plans, specifications and contract documents to the City for construction use by the City and Contractor. Part IV: Construction Phase A. Attend a pre -construction conference, including preparing an agenda. B. Attend coordination meetings with contractor, quality control personnel, and City representatives to discuss strategy, problem areas, progress, and any required coordination. C. Review shop drawings and other submittal information, which the Contractor submits. This review is for the benefit of the Owner and covers only general conformance with information given by the Contract Documents. The contractor is to review and stamp their approval on submittals prior to submitting to the Engineer. Review by the Engineer does not relieve the Contractor of any responsibilities, safety measures or the necessity to construct a complete and workable facility in accordance with the Contract Documents. TWE Firm 526 ACEC AHP Firm -=;) Better Decisions -Better Designs TBPLS Firm 100318-00 1:\7015 conldevtanna\201 B Iwnicana cretk regional somMurricano creek regional sanitary sewer task order.doar Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitaty Sewer June 6, 2018 Page 6 of 13 D. Provide written responses to requests for information or clarification to City or Contractor. E. Prepare and process routine change orders for this project as they pertain to the original scope of work. F. Make periodic site visits during construction as the project requirements dictate. Minimum of one project site visit per month. G. Review monthly pay request from information obtained in the field. H. Accompany the City during their final inspection of the project. I. Recommend final acceptance of work based on information from the on-site representative. I Prepare Record Drawings. Utilizing on-site representative and Contractor construction record information, consultant will prepare electronic image files in Adobe Acrobat file format and ACAD.dwg file format. Part V: Additional Services A. Design, Property and Construction Control Surveys B. Preparation of Plat and Field Note Descriptions for expected sanitary sewer easements required. Thirty-six (36) easement descriptions are included for the purpose of establishing a budget for this phase of work. C. Clearing of the proposed project route for access by the Geotechnical equipment and field surveys as required. D. Additional Design & Coordination meetings with project stakeholders above and beyond those identified in Part I and Part II (H). E. Geotechnical Evaluations and recommendations. The Geotechnical evaluation and report will be performed by a sub -consultant to be approved by the City of Anna. F. Printing of final plans and specifications for distribution to prospective bidders and the successful contractor. WE Firm 526 ACEC AHIP Finn =;� Better Decisions -Better Designs TBPLS Firm 100318-00 1:17015 conideAanna\2018 hurricane week regional seweAhurTlcane creek reglonaI son11ary sewer task ordecdocx Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 7 of 13 Part V: Exclusions The intent of this scope of services is to include only the services specifically listed herein and none others. Services specifically excluded from this scope of services include, but are not necessarily limited to the following: A. Environmental impact statements and assessments. B. Fees for permits or advertising. C. Certification that work is in accordance with plans and specifications. D. Environmental cleanup. E. Fiduciary responsibility to the City. F. Trench safety designs. G. Quality control and testing services during construction. H. Services in connection with condemnation hearings. 1. Phasing of Contractor's work. J. On-site safety precautions, programs and responsibility. K. Consulting services by others not included in proposal. L. Revisions and/or change orders as a result of revisions after completion of original design (unless to correct error on plans). M. Traffic engineering report or study. N. Title searches. 0. Land Rights Acquisition Services TBPE Firin 526 ACECAHIP Firm Better Decisions -Better Designs TEAS Firm 100318-00 1:57015 contdevlennW018 hurricane creek regional sewer\hurricane creek regional sanilery sewer ask order. docx 00 - °-° rn o N0 N N -t+ 00 00 00 00 O N CAN O, O, u N O O N O N p N O p N 00 N Ef •y' N N N .L1 .O lQ Q7 .fl ti A A A w w d 0 w 00 00 CS D - C) q p 00 00 (' N q O 4a FM+ N 00 N DO a (IL C11 m a N z A d d z A A A d 00 A 00 0 rn � rn u oHo 00 N r N q N o �• a\ N N N N N d� "i N vi N N N 00 '+ N M i, ti C ����� .� o z •� d o ff 00 00 d Cl N� q O N q N q �y u 00 00 N N �O 0� NO N p N N O N O NO p N pN N a~i a�"ii � 0O N N ko N N N O Nqr a�"i a4i o 0o n a v ai ami 00 - ON N 00 00 N 00 00 H N N N N o, o, p N o O N N N to er �- N .- N o N ,M O N A ko 00 N y a+ 04 b .OU m Cl in o o ti ti d vT 00 00 00 00 00 N C) N C1 N N O, O, 00 r+, ,�, N N N O N •� N OC4(� N N ami w N N q pycq .q .� �` N b o an t b P4 p cn W o q an o 0 �t a 6b 6b 0 P-4 o j0 E� ,Zo W a fA V Gq c� U Q\ a 0 Z U Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 9 of 13 TEE NOT TO EXCEED AMOUNT City may choose to authorize any or all of the six (6) project elements without affect to the scope of services or fee to any project elements not authorized at this time. Preliminary Engineering - Basic Services Payment for the Preliminary Engineering Design Phase portion of the Basic Services described under Parts 1 shall be on a Lump Sum Basis in the following Amounts: Resolution This Resolution Preliminary Engineering - Additional Services For the Additional Services included with the preliminary engineering, we propose to be compensated on a salary cost basis times a multiplier of 2.41, with expenses at actual invoice cost times 1.15. The survey crew will be billed at a crew rate of $165 per hour. Automobile mileage for additional Zlution voiced at $0.55 per mile. 06-456 We sugges pro imately $327,625 in the following amounts for our services for this nroiect: aTThi� Resolution LUU-Ub-4�(� Project B Pro' C Project D Project E Project F Total A. Design and Part I Pro'ec Project B Pro' t C Project D Project E Project F Total A. Preliminary $10,000 $8,000 $3,500 $8,000 $5,000 $5,000 $39,500 Engineering Report $7,000 $28,000 $14,000 $14,000 $126,000 and Field Note B. Preliminary $240,379 $99,723 $43,605 $127,040 $40,389 $49,141 $595,102 Alignment & Grade C. Route Clearing $40,000' Toti Prelim $250,379 $107,723 $47,105 $135,040 $45,389 $54,141 $634,602 Engineering Basic $1,000 $3,000 $2,000 $2,000 $16,000 Meetings Service Total Prelim $112,375 Preliminary Engineering - Additional Services For the Additional Services included with the preliminary engineering, we propose to be compensated on a salary cost basis times a multiplier of 2.41, with expenses at actual invoice cost times 1.15. The survey crew will be billed at a crew rate of $165 per hour. Automobile mileage for additional Zlution voiced at $0.55 per mile. 06-456 We sugges pro imately $327,625 in the following amounts for our services for this nroiect: aTThi� Resolution TBPE Firm 526 ACECAHIP Firm =:� Better Decisions - Better Designs TBPLS Firm 100318-00 IA701 S cnnIdcY\nnnn\2018 hurricane creek regional sewer\harricane creek regional sanitary sewor [ask order docx Project A Project B Pro' C Project D Project E Project F Total A. Design and $28,875 $19,250 $9,625 $19,250 $11,000 $12,375 $100,375 Boundary Surveys B. Preparation of Plat $38,500 $24,500 $7,000 $28,000 $14,000 $14,000 $126,000 and Field Note Descriptions C. Route Clearing $40,000' $22,250 $20,000 $3,000 $85,250 D. Additional Design $5,000 $3,000 $1,000 $3,000 $2,000 $2,000 $16,000 Meetings Total Prelim $112,375 $69, 00 $17,625 $70,250 $30,000 $28,375 $327,625 Engineering Additional Service This ResOlUtion Not to Exceed Amounts TBPE Firm 526 ACECAHIP Firm =:� Better Decisions - Better Designs TBPLS Firm 100318-00 IA701 S cnnIdcY\nnnn\2018 hurricane creek regional sewer\harricane creek regional sanitary sewor [ask order docx Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June 6, 2018 Page 10 of 13 Final Design - Basic Services Payment for the Final Design Phase portion of the Basic Services described under Parts II, III and, IV shall be on a Lump Sum Basis in the following Amounts: This Resolution Final Design - Additional Services For the Additional Services to be included in the Final Design, we propose to be compensated on a salary cost basis times a multiplier of 2.41, with expenses at actual invoice cost times 1.15. Automobile mileage for additional services will be invoiced at $0.55 per mile. We suggest you budget approximately $46,750 in the following amounts for our services for this project; _ This Resolution Project A oject B Project C Project D Project E Project F Total E. Geotechnical $9,850 t $6,300 $9,900 $4,300 $5,200 $41,100 Part II: Design Phase $160,253 $66,482 $29,070 $84,694 $26,926 $32,761 $396,736 (Final Part III: Bidding Phase $16,025 $11,080 $4,845 $14,116 $4,488 $8,736 $58,715 Part IV: Construction $117,519 $44,321 $19,380 $56,462 $17,951 $18,565 $271,898 Phase $11,350 $6 r 750 $6 > 8000 $11,100 $4, 800 $5,950 $4650 , 7 Total Basic Services Lump Sum Fee $293,797 $121.,883 $53,295 _ $155,275 $49,365 $60,062 $733,677 Final Design - Additional Services For the Additional Services to be included in the Final Design, we propose to be compensated on a salary cost basis times a multiplier of 2.41, with expenses at actual invoice cost times 1.15. Automobile mileage for additional services will be invoiced at $0.55 per mile. We suggest you budget approximately $46,750 in the following amounts for our services for this project; _ This Resolution Texas Board of Professional Land Surveying Contact Information Recipients of professional land surveying services under this agreement may direct complaints regarding such services to the Texas Board of Professional Land Surveying, 12100 Park 35 Circle, Building A, Suite 156, MC 230, Austin, TX 78753, Phone (512) 239-5263, Fax (512) 239-5253. WE Firtn 526 ACEC AMP Firm Better Decisions - Better Designs WLS Firm 100318-00 1:17015 contdev\enna\20i8 hurricane creek regional sowerlhvniana neck mg1onni sanitary sewer task order.doex Project A ro'ect B Project C Project D Project E Project F Total E. Geotechnical $9,850 $5,550 $6,300 $9,900 $4,300 $5,200 $41,100 Evaluation and Report F. Printing of Plans & $1,500 $1,200 $500 $1,200 $500 $750 $5,650 Specifications Total Additional Service $11,350 $6 r 750 $6 > 8000 $11,100 $4, 800 $5,950 $4650 , 7 Not to Exceed Amounts Texas Board of Professional Land Surveying Contact Information Recipients of professional land surveying services under this agreement may direct complaints regarding such services to the Texas Board of Professional Land Surveying, 12100 Park 35 Circle, Building A, Suite 156, MC 230, Austin, TX 78753, Phone (512) 239-5263, Fax (512) 239-5253. WE Firtn 526 ACEC AMP Firm Better Decisions - Better Designs WLS Firm 100318-00 1:17015 contdev\enna\20i8 hurricane creek regional sowerlhvniana neck mg1onni sanitary sewer task order.doex Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitary Sewer June G, 2018 Page 1 l of 13 If this General Engineering Services Agreement Task Order meets with your approval, please sign and return one set to our office along with your directive to proceed. We look forward to working with you on this important project for the City of Anna and are available to discuss this task further at your convenience. Sincerely yours, /CraiMlrykhoff, P.E., C.F.M. Partner ATTEST: 563 Gary C endricks, Alter ate Managing Partner PRELIMIA Y ENGINEERING APPROVED FOR THE CITY OF ANNA, TEXAS l By 1 Mr. Maurice Schwanke, City Manager Date FINAL DESIGN APPROVED FOR THE CITY OF ANNA, TEXAS By: C �� Mr. Maurice Schwanke, City Manager Date TBPE Firm 526 .ACEC AHIP Firer =;� Better Decisions - Better Designs TBPLS Firm 100318-00 IA70IS eonldevlanna\2018 hunica no creek regional seweAhuffieanecreek regional sanitarystwer task order dost Mr. Joseph Johnson General Services Task Order: Hurricane Creek Sanitaty Sewer June 6, 2018 Page 12 of 13 Exhibit A - Project Location Map PROJECT 0 (4,650 L.F. 30") (4,400 L.F, 27") CITY OF ANNA, TEXAS 77777 HURRICANE CREEK REGIONAL TRUNK SEWER CONCEPTUAL ALIGNMENT 7�4� h + Y r• 1 PROAECT—B - (1,400 L.F. 33") (8,100 L.F. 30") PROJECT C (3,750 L.F. 18") — �" J I Is ILL 1 *. u� r•I;tURB CtlI 11K COUNI,'iIIrlPx llxlP I __' f.. - II PROJECT (15,250 L,F, li—J -- 01n 01OFF, HEN )R CX8 & CARTER, L.L.P. t%UY65 1110 Al,Y.1:tlINPJ7tS /'."J�+ I:,r'11IFil\„7 IIttSMIJI \•,.Irn)Ir',•, I,rW.. 1,„ 1111�11•HI•r+111•„,`1 / (r 5' �```��_. MAY.1tl1a sY �'f �1.'1 a"\\\i\"vili-•. t �['1:I 4,��1 PROJECT (5,000 L.F. 12")• TJ f PROJECT F (5,700 L.F. 15") WE firm 526 ACLC AHIP Ron =�% Better Decisions - Better Designs 7BPLS Fina 100318-00 1:\7015 conldev\anna\2018 hurricane creek regional smverlhurricane creek regional sanilary sewer ink ordecdocx Mr. Josephs Johnson General Services Task Order; Hurricane Creek Sanitary Sewer June 6, 2018 Page 13 of 13 Appendix A — Opinion of Probable Project Cost (Follows this page) TBPE Firm 526 ACECAHIP Firm =;� Better Decisions - Better Designs TBPLS r, Inn 1:17015 wnldeAuna12018 hurricane creek reglonnl seweAhurrlcane creek regional sanitary newer task order dow BIRKIIOFF, HENDRICKS & CARTER, L.L.P. Project No. PROFESSIONAL ENGINEERS Texas Fir>u F526 Client: City of Anna, Texas Date: Project: Hurricane Creek Regional Trunk Sewer Project A - 15,250 L.F. 36 -Inch PVC Sanitary Sewer By: ENGINEER'S OPINION OF CONSTRUCTION COST Project A 6 -Jun -18 CMK Item No. Description lQuantityl Unit I Price I Amount 1 Furnish & Install 36 -Inch Sanitary Sewer w/Embedment by Open Cut 14,650 L.F. $ 200.00 $ 2,930,000.00 2 Furnish & Install 36 -Inch Sanitary Sewer w/Steel Encasement Pipe by Oen Cut (Collin County Outer Loo) 500 L.F. $ 1,500.00 $ 750,000.00 3 Furnish & Install 36 -Inch Sanitary Sewer Creek Crossing 100 L.F. $ 2,000.00 $ 200,000.00 4 Furnish & Install 6 -Foot Diameter Manhole w/Pressure Type Frame & Cover w/E oxy Coating (15 -foot Depth) 9 Ea. $ 16,000.00 $ 138,000.00 5 Furnish & Install 6 -Foot Diameter Manhole w/Pressure Type Frame & Cover & Vent Assembly w/Epoxy Coating (15 -foot Depth) 30 Ea. $ 20,000.00 $ 600,000.00 6 Furnish & Install Flow Meter i Ea. $250,000.00 $ 250,000.00 7 Furnish, Install, Water, Fertilize & Establish Hydromulch 67,334 S.Y. $ 4.00 $ 269,336.00 8 Furnish Trench Safety Plan 1 L.S. $ 4,000.00 $ 4,000.00 9 Implement Trench Safety Plan 15,250 L.F. $ 7.00 $ 106,750.00 10 Furnish Storm Water Pollution Prevention Plan I L.S. $ 5,000.00 $ 5,000.00 11 Furnish, Install, Maintain & Remove Erosion Control Measures 15,250 L.F. $ 2.00 $ 30,500.00 12 Furnish, Install, Maintain & Remove Traffic Control Measures 1 L.S. $ 25,000.00 $ 25,000.00 Construction Subtotal: $ 5,308,586.00 Contingencies and Miscellaneous Items 15% $ 796,288.00 Construction Total: $ 6,104,874.00 Bonds, Insurance and Mobilization 2% $ 122,097.48 Land Rights Acquisition (40 -Ft Permanent San. Sew. Easement): 15 Ac. $ 50 000.00 $ 750,000.00 Professional Services: $612,901 Inspection Services 1.5% $ 91,573.11 Materials Testing: 2.5% $ 152,621.85 Project Total: $ 7,834,067.44 USE: $ 7,835 000.00 LA7015 ContDavV,nna\201 A Hurricane Creek Regiunal 8eNYcAPrcJWnary FOC w Mantua As Page I of I BIRKHOFF, HEN RICKS & CARTER, L.L.P. PROFESSIONAL ENGINEERS Texas Firm FS26 Client: City of Anna, Texas Project Hurricane Creek Regional Trunk Sewer Project B -1,400 L.F. 33 -Inch & 8,100 L.F. 30 -Inch PVC Sanitary Sewer Project No. Project B Date: 6 -Jun -18 By: CMK ENGINEER'S OPINION OF CONSTRUCTION COST (tem Nol Description lQuantityl Unit I Price I Amount 1 Furnish & Install 33 -Inch PVC Sanitary Sewer w/Embedment by Open Cut 1,400 L.F. $ 175.00 $ 245,000.00 2 Furnish & Install 30 -Inch PVC Sanitary Sewer w/Embedment by Open Cut 8,100 L.F. $ 150.00 $ 1,215,000.00 3 Furnish & Install 6 -Foot Diameter Manhole w/Pressure Type Frame & Cover w/E oxy Coating (15 -foot Depth) 17 Ea. $ 16,000.00 $ 268,000.00 4 Furnish & Install 6 -Foot Diameter Manhole w/Pressure Type Frame & Cover & Vent Assembly w/Epoxy Coating (15 -foot Depth) 9 Ea. $ 20,000.00 $ 180,000.00 5 Furnish, Install, Water, Fertilize & Establish H dromulch 4,667 S.Y. $ 4.00 $ 18,668.00 6 Famish Trench Safety Plan I L.S. $ 3,000.00 $ 3,000.00 7 Implement Trench Safety Plan 9,500 L.F. $ 7.00 $ 66,500.00 8 Furnish Storm Water Pollution Prevention Plan 1 L.S. $ 4,000.00 $ 4,000.00 9 Furnish, Install, Maintain & Remove Erosion Control Measures 9,500 L.F. $ 2.00 $ 19,000.00 10 Fumish, Install, Maintain & Remove Traffic Control Measures 1 L.S. $ 20,000.00 $ 20,000.00 Construction Subtotal: $ 2,039,168.00 Contingencies and Miscellaneous Items 15% $ 305,876.00 Construction Total: $ 2,345,044.00 Bonds, Insurance and Mobilization 2% $ 46,900.88 Land Rights Acquisition (30 -Ft Permanent San. Sew, Easement): 7 Ac. $ 50,000.00 $ 327,134.99 Professional Services: $272,106 Inspection Services 1.5% $ 35,175.66 Materials Testing: 2.5% $ 58,626.10 Project Total: $ 3,084,987.63 USE: $ 3,085,000.00 LA7015 CanfDev naA2016 Hurricane Ctcek Regional SewcAPreliminary ROC w Manwaxls Page 1 of 1 BIRKHOFF, HENDRICKS & CARTER, L.L.P. PROFESSIONAL ENGINEERS Texas Ftrnt F526 Client: City ofAnna, Texas Project: Hurricane Creek Regional Trunk Sewer Project C - 3,750 L.F, 18 -Inch PVC Sanitary Sewer Project No. Project C Date: 6 -Jun -18 By: ENGINEER'S OPINION OF CONSTRUCTION COST JRI Item No, I Description JQuanfi(yl Unit I Price I Amount 1 Furnish & Install 18 -Inch PVC Sanitary Sewer w/Embedment by Open Cut 3,550 LY, $ 120.00 $ 426,000.00 2 Furnish & Install 18 -Inch PVC Sanitary Sewer Creek Crossing 200 L.F. $ 500.00 $ 100,000.00 3 Furnish & Install 5 -Foot Diameter Manhole w/Pressure Type Frame & Cover w/E oxy Coating (15 -foot Depth) 7 Ea. $ 12,000.00 $ 88,500.00 4 Furnish & Install 5 -Foot Diameter Manhole w/Pressure Type Frame & Cover & Vent Assembly w/Epoxy Coating (15 -foot Depth) 4 Ea. $ 16,000.00 $ 64,000.00 5 Furnish, Install, Water, Fertilize & Establish Hydromulch 11,834 S.Y. $ 4.00 $ 47,336.00 6 Furnish Trench Safety Plan l L.S. $ 3,000,00 $ 3,000.00 7 Implement Trench Safety Plan 3,750 L.F. $ 7.00 $ 26,250.00 8 JFurnish Storm Water Pollution Prevention Plan I L.S. $ 4,000.00 $ 4,000.00 9 Fumish, Install, Mauitain & Remove Erosion Control Measures 3,750 L.F. $ 2.00 $ 7,500.00 10 Furnish, install, Maintain & Remove Traffic Control Measures l L.S. $ 10,000.00 $ 10,000.00 Construction Subtotal: $ 776,586.00 Contingencies and Miscellaneous Items 15% $ 116,488.00 Construction Total: $ 893,074.00 Bonds, Insurance and Mobilization 2% $ 17,861.48 Land Rights Acquisition (40 -Ft Permanent San, Sew. Easement): 4 Ac. 1 $ 50,000.00 $ 200,000.00 Professional Services: $120,325 Inspection Services 1.5% $ 13,396.11 Materials Testing: 2.5% $ 22,326.85 Project Total; $ 1,266,983.44 USE: $ 1,267,000.00 LA7015 ConIDcAAmia\2018 Hurricane Geek Regional SeeeAPreliminary EEC w Monlua xla Page / of I BIRKHOFF, HENDRICKS & CARTER, L.L.P. PROFESSIONAL ENGINEERS Texas Finn F526 Project No. Project D Client: City of Anna, Texas Date: Project: Hurricane Creek Regional Trunk Sewer Project D -5,100 L.F. 30 -Inch & 4,400 L.F. 27 -Inch PVC Sanitary Sewer By: ENGINEER'S OPINION OF CONSTRUCTION COST 6 -Jun -18 CMK Item No. Description I Quantltyl Unit I Price I Amount 1 & Install 30 -Inch PVC Sanitary Sewer w/Embedment by Open Cut 4,980 L.F. $ 180.00 $ 896,400.00 F2Furnish Furnish & Install 27 -Inch PVC Sanitary Sewer w/Embedment b Open Cut 4,400 L.F. $ 165.00 $ 726,000.00 3 Furnish & Install 30 -Inch PVC Sanitary Sewer wl Steel Encaasement by Other Open Cut 120 L.F. $ 1,200.00 $ 144,000.00 4 Furnish & Install 6 -Foot Diameter Manhole w/ Pressure Type Frame and Cover and w/ Epoxy Coating (15 -foot Depth) 17 Ea. $ 16,000.00 $ 279,200.00 5 Furnish & Install 6 -Foot Diameter Manhole w/Pressure Type Frame & Cover & Vent Assembly w/Epoxy Coating (15 -foot Depth) 8 Ea. $ 20,000.00 $ 160,000.00 6 Furnish & Install Flow Meter 1 Ea. $250,000.00 $ 250,000.00 7 Furnish, Install, Water, Fertilize & Establish Hydromulch 31,267 S.Y. $ 4.00 $ 125,068.00 8 Furnish Trench Safety Plan I L.S. $ 3,000.00 $ 3,000.00 9 Implement Trench Safety Plan 9,380 L.F. $ 7.00 $ 65,660.00 10 Furnish Storm Water Pollution Prevention Plan I L.S. $ 4,000.00 $ 4,000.00 11 Furnish, Install, Maintain & Remove Erosion Control Measures 9,380 L.F. $ 2.00 $ 18,760.00 12 Furnish, Install, Maintain & Remove Traffic Control Measures 1 L.& $ 5,000.00 $ 5,000.00 Construction Subtotal: $ 2,677,088.00 Contingencies and Miscellaneous Items 15% $ 401 564.00 Construction Total: $ 3,078,652.00 Bonds, Insurance and Mobilization 2% $ 61,573.04 Land Rights Acquisition (30 -Ft Permanent San. Sew. Easement): 6 Ac. 1 $ 50,000.00 $ 323,002.75 Professional Services: $340,662 Inspection Services 1.5% $ 46,179.78 Materials Testing: 2.5% $ 76,966.30 Project Total: $ 3,927,035.87 USE: $ 3,928,000.00 LA7015 ConlDevVuma\2018 Hurricane Creek Regional SeweAPteliminary EQC w Mantua xis Page 1 of 1 BIRKHOFF, HENDRICKS & CARTER, L.L.P. PROFESSIONAL ENGINEERS Texas Firfn F526 Client: City of Anna, Texas Project: Hurricane Creek Regional Trunk Sewer Project E - 5,000 L.F. 12 -Inch PVC Sanitary Sewer Project No. Project E Date: 6 -Jun -18 By: CMK ENGINEER'S OPINION OF CONSTRUCTION COST Item No. I Description Quantityl Unit I Price I Amount 1 Furnish & Install 12 -Inch PVC Sanitary Sewer w/Embedment by Open Cut 5,000 L.F. $ 80.00 $ 400,000.00 2 Furnish & Install 5 -Foot Diameter Manhole w/Epoxy Coating (15 -foot Depth) 13 Ea. $ 12,000.00 $ 1$0,000.00 3 Furnish & Install 5 -Foot Diameter Manhole w/Pressure Type Frame & Cover w/E oxy Coating (15 -foot Depth) 2 Ea. $ 16,000.00 $ 32,000.00 4 Furnish, Install, Water, Fertilize & Establish H dromulch 16,667 S.Y. $ 4.00 $ 66,668.00 5 Furnish Trench Safety Plan 1 L.S. $ 3,000.00 $ 3,000.00 6 Implement Trench Safety Plan 5,000 L.F. $ 7.00 $ 35,000.00 7 Furnish Storm Water Pollution Prevention Plan I L.S. $ 4,000.00 $ 4,000.00 8 Finnish, Install, Maintain & Remove Erosion Control Measures 5,000 L.F. $ 2.00 $ 10,000.00 9 Furnish, Install, Maintain & Remove Traffic Control Measures 1 L.S. $ 5,000.00 $ 5,000.00 Construction Subtotal: $ 705,668.00 Contingencies and Miscellaneous Items 15% $ 105,851.00 Construction Total: $ 811,519.00 Bonds, Insurance and Mobilization 2% $ 16,230.38 Land Riehts Acauisition f30 -Ft Permanent San. Sew. 07015 ComDeAAnn12018 Hunicane Creek Regional Sewcf\PrcllminaryEOC w \ivmmxis Page 1 of I BIRK%IOFF, HENDRICKS & CARTER, L.L.P. PROFESSIONAL ENGINEERS Teras Firm F526 Client: City of Anna, Texas Project: Hutricane Creek Regional Trunk Sewer Project F - 5,700 L.F. 15 -Inch PVC Sanitary Sewer Project No. Project F Quantityl Date: 6 -Jun -18 I Amount By: _ CMK ENGINEER'S OPINION OF CONSTRUCTION COST Item No. I Description Quantityl Unit Price I Amount 1 Fumish & Install 15 -Inch PVC Sanitary Sewer w/Embedment by Oen Cut 5,600 L.F. $ 95.00 $ 532,000.00 2 Fumish & Install 15 -Inch PVC Sanitary Sewer Creek Crossing 100 L.F. $ 350.00 $ 35,000.00 3 Fumish & Install 5 -Foot Diameter Manhole w/Epoxy Coating (15 -foot De th) 16 1 Ea. $12,000.00 $ 192,000.00 4 Furnish, Install, Water, Fertilize & Establish H dromulch 18,667 S.X, $ 4.00 $ 74,668.00 5 Fumish Trench Safety Plan l L.S. $ 3,000.00 $ 3,000.00 6 Implement Trench Safety Plan 5,700 L.F. $ 7.00 $ 39,900.00 7 Furnish Storm Water Pollution Prevention Plan 1 L.S. $ 4,000.00 $ 4,000.00 8 Furnish, Install, Maintain & Remove Erosion Control Measures 5,700 L.F. $ 2.00 $ 11,400.00 9 Fumish, Install, Maintain & Remove Traffic Control Measures I L.S. $10,000.00 $ 10,000.00 Construction Subtotal: $ 901,968.00 Contingencies and Miscellaneous Items 15% $ 135,296.00 Construction Total: $ 1,037,264.00 Bonds, Insurance and Mobilization 2% $ 20,745.28 Land Rights Acquisition (30 -Ft Permanent San, Sew. Easement): 4 Ac. $ 50,000.00 $ 196,280.99 Professional Services: $141,528.00 Inspection Services 1.5% $ 15,558.96 Materials Testing: 2.5% $ 25,93I.60 Project Total: $ 1,437,308.83 USE:$ 1,438,000.00 LA7015 Con1Dev\AMA2018 Hurricane Creek Neglanal SewefTrelWnary LOC w Mantua AS Page I of I CERTIFICATE OF INTERESTED PARTIES FORM 1295 loft Complete Nos. 1- 4 and 6 if there are Interested parties. OFFICE USE ONLY Complete Nos. 1, 2, 3, 5, and 6 If there are no interested parties. CERTIFICATION OF FILING Certificate Number: 1 Name of business entity filing form, and the city, state and country of the business entity's place of business, 2018-964696 Birkhoff, Hendricks & Carter Dallas, TX United States Date Filed: 06/06/2018 2 Name of governmental entity or state agency that Is a party to the contract for which the form Is being filed. City of Anna Date Acknowledged: a Provide the Identification number used by the governmental entity or state agency to track or Identify the contract, and provide a description of the services, goods, or other property to be provided under the contract. Hurricane Creek Regional Sewer Professional Engineering Services 4 Nature of Interest Name of Interested Party City, State, Country (place of business) (check applicable) Controlling I intermediary Birkhoff, John Dallas, TX United States X Hendricks, Gary Dallas, TX United States X Carter, Joe Dallas, TX United States X Hickey, Matthew Dallas, TX United States X Mata, Andrew Dallas, TX United States X 5 Check only if there is NO Interested Party, ❑ 6 UNSWORN DECLARATION My name is Cralg M. Keikhoff and my date of birth is October 10, 1082 My address Is 11910 Qreanville Ave, Suite 600 Dallas Texas 75243 USA 1 (street) (elly) (state) (zip code) (country) I declare under penalty of perjury that the foregoing Is true and correct. Executed In Dallas County, State of Texas on the 6th day of June 20e-16 (month) (year) Signature of a ihorized agent of contracting business entity (Declarant) Forms provlaea by Texas Ethics Commission www.ethics.state,tx.us Version V1.0,5523 CITY OF ANNA, TEXAS A RESOLUTION OF THE CITY OF ANNA, TEXAS APPROVING AND AUTHORIZING THE CITY MANAGER TO ACT ON THE CITY'S BEHALF IN EXECUTING AN ENGINEERING TASK ORDER WITH BIRKHOFF, HENDRICKS & CARTER, LLP FOR THE HURRICANE CREEK REGIONAL SEWER PROJECT. WHEREAS; The City of Anna, Texas (the City) has negotiated an engineering service task order with Birkhoff, Hendricks & Carter, LLP for the Hurricane Creek Regional Sewer Project (the Project); and, WHEREAS; the Project will provide the necessary engineering services to enable easement acquisition with only Projects A & B being the initial focus; and, WHEREAS; the engineering services fee for Project A, Part I is in the amount of $250,379 and Part V is in the amount of $67,375; and Project B, Part I is in the amount of $107,723 and Part V is in the amount of $43,750 for a total not -to exceed amount of $469,227; and, WHEREAS; funds are available for the project using collected wastewater impact fees; and, WHEREAS; the Project supports the City's adopted Strategic Plan goals of pursuing targeted economic development and upgrading City facilities and infrastructure; NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ANNA, TEXAS, THAT: Section 1. Recitals Incorporated. The recitals above are incorporated herein as if set forth in full for all purposes. Section 2. Authorization. The City Council hereby approves Parts I and V for Project A and B of the Agreement attached hereto as Exhibit 1, and authorizes, ratifies and approves the City Manager's execution of same. The City Manager is hereby authorized to execute all documents and to take all other actions necessary to finalize, act under, and enforce the task order agreement. PASSED AND APPROVED by the City Council of the City of Anna, Texas, on this 26th day of June 2018. APPROVED: Mayor Nate RESOLUTION: Hurricane Creek Regional Sewer OF AIV "''''•,, k'i31tder.T EX Pn��`��`PA ATTEST: City Secretary Carrie L. Smith I OF I 6/26/18